A PAS request can be technically valid yet include clinical information that is irrelevant to the service being authorized. The current Da Vinci PAS v2.2.1 guide makes room for a provider or designated agent to review patient information before it is sent and, where appropriate, amend or withhold the submission. It also says implementations must permit that review without making it mandatory. The useful design question is therefore concrete: what can a reviewer see, change, and verify before the final Claim Bundle leaves the organization? This guide addresses that workflow. It does not determine what disclosure a particular law, payer contract, or patient consent permits.

Start with the service and its evidence request

Build a review screen around the requested service, not around every record the EHR can retrieve. Show the payer and coverage selected for this request, the Claim items, the proposed service dates, and the reason each supporting resource was added. PAS describes several forms of supporting information: provider attestations in QuestionnaireResponse, structured clinical resources, and documents such as reports or notes. The reviewer needs to distinguish these forms because a short attestation, a discrete result, and a full PDF disclose different amounts of detail.

For each evidence item, show the source, date, status, and the Claim item or question it supports. A DTR-prefilled answer should remain identifiable as an answer, while its source resource remains visible when it is being transmitted. If an attachment was selected automatically, show the document title and a preview or safe link to its contents. Do not present a filename as a substitute for reviewing the actual document. When the payer requirement is unclear, route the case for a policy or clinical review instead of assuming that more data is always better.

  • Show the exact payer, coverage, service line, and evidence purpose.
  • Separate attestations, structured resources, and document attachments.
  • Expose the content and provenance of any automatically selected document.

Make review optional while preserving a real choice

PAS v2.2.1 states that a provider or designated agent must have the ability to review patient information and, where appropriate, amend or withhold submission. The same use-case requirement allows the provider to turn off documentation review; the vendor must allow that option. The privacy section restates the boundary: permit provider review, but do not require it. A product can therefore support a configured straight-through path while still offering an accessible review action when the organization chooses to use it.

In a review path, distinguish three actions. Keep means the item remains in the outgoing package. Correct means the source data or selected representation needs repair before submission. Withhold means the item or the whole submission is held back for an appropriate decision. The workflow should not silently delete an item from the request after a reviewer sees it. Record who made the choice and which request version was reviewed so the assembled payload can be compared with the submitted payload. These are implementation controls, not a substitute for organizational privacy policy or legal review.

  • Provide a visible review route even when straight-through processing is configured.
  • Distinguish correction from withholding and from ordinary removal of a duplicate.
  • Retain a trace of the reviewed request version and final payload.

Rebuild the Bundle after any change

The PAS technical specification requires a JSON Bundle whose first entry is a PAS Claim. It requires the Bundle to include resources referenced by the Claim and to traverse references from those resources. Supporting information in the Bundle must be pointed to by Claim.supportingInfo.valueReference. A reviewer action that removes a document, changes a QuestionnaireResponse, or substitutes a corrected result therefore changes more than one screen row: it can change the reference graph and the Claim's supportingInfo entries.

After a change, regenerate the outgoing Bundle and check it as a whole. Confirm that every retained supporting resource is still linked from the Claim, every required referenced resource is present, and a removed resource is not still reachable through an obsolete reference. If the reviewer withholds the entire request, stop before invoking Claim/$submit. If the reviewer replaces a PDF, inspect the new DocumentReference and its attachment rather than assuming the new file inherits the old review. A submission log should capture the final Bundle identity and transmission outcome, not merely the pre-review draft.

  • Regenerate Claim.supportingInfo after each evidence change.
  • Validate referenced resources and document content before submit.
  • Compare the final transmitted Bundle with the reviewed version.

Test the decision points with realistic cases

Use a fixture with an attestation, a structured Observation, and a DocumentReference, all tied to a single authorization request. Test a reviewer keeping all three, correcting the Observation, removing a duplicate document, and withholding the whole submission. Include a case where a document preview fails and a case where a supporting resource references another resource. Each branch should leave either a valid final Bundle or an explicit hold state. An absent preview must not be interpreted as approval to send an unreadable attachment.

For a privacy-focused regression, seed a document containing content outside the stated evidence purpose. Verify that the reviewer can identify and route it under the organization's disclosure policy, and that the final package reflects the decision. PAS notes that security labels on FHIR resources are not currently mappable into X12 275 and 278, so downstream handling cannot be assumed from a FHIR label alone. The review should end with a clear handoff: submitted, held for correction, or withheld, with the final source and version available to the team handling follow-up.

Primary references